On the left the starting wastewater, on the right the wastewater at the end of the test

Jar test of waste water from galvanic processes

Year
2025
Sector
APPLICATION:

Waste water from galvanic proccesses with high concentrations of metals in solution.

DESCRIPTION:

The wastewater is first subjected to a pH adjustment and the addition of a coagulating agent. A flocculation agent is then dosed and an alkaline pH is maintained to promote the formation of sludge. The sample is tested to verify the reduction of metals, specifically boron.

TECHNICAL DATA:
PARAMETERS PRE-TEST POST-TEST
SST 120 [g/l] 52 [g/l]
pH 2.5 11
BORON 1086 [mg/l] 30 [mg/l]
COPPER 1900 [mg/l] 1.3 [mg/l]
NICKEL 7118 [mg/l] 9.7 [mg/l]
ZINC 123 [mg/l] 0.6 [mg/l]
HIGHLIGHTS:
  • Boron reduction by 97.3%
  • Copper reduction by 99.9%
  • Nickel reduction by 99.9%
  • Zinc reduction by 99.5%