On the left is the concentrate, in the center is the condensate at 65°C, on the right is the condensate at 45°C

Evaporation of water from chemical-physical plant

Year
2025
APPLICATION:

Double-effect vacuum evaporation of chemical-physical water treatment plant effluent.

DESCRIPTION:

A vacuum evaporation test is performed, divided into two stages with different vacuum degrees and temperatures, simulating a double-effect system. The test is performed to improve the characteristics of previously treated water to facilitate its direct recycling.

TECNICHAL DATA:
PARAMETERS PRE-TEST CONDENSATE 1st Stage CONDENSATE 2nd Stage
pH 7,6 9,4 6,8
EC [µS/cm] 3969 134 20
COD [mg/l O₂] 208 127 173

 

HIGHLIGHTS:
  • Recovery of 95% of the volume as clear, colorless water with low salt content;
  • Formation of 5% liquid concentrate by volume, which is a pumpable;
  • Treatment of large volumes of water with a single evaporator.

Other case history

Please contact us directly

for the full list of our activities and a quote